896 resultados para Stiles-Crawford effect, accommodation, myopia, psychophysical technique, multifocal electroretinogram, aberrations, accommodative lag


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Mechanical forces either due to accommodation or myopia may stretch the retina and/or cause shear between the retina and choroid. This can be investigated by making use of the Stiles-Crawford effect (SCE), which is the phenomenon of light changing in apparent brightness as it enters through different positions in the pupil. The SCE can be measured by psychophysical and objective techniques, with the SCE parameters being directionality (rate of change across the pupil), and orientation (the location of peak sensitivity in the pupil). Aims: 1. To study the changes in foveal SCE with accommodation in emmetropes and myopes using a subjective (psychophysical) technique. 2. To develop and evaluate a quick objective technique of measuring the SCE using the multifocal electroretinogram. Methods: The SCE was measured in 6 young emmetropes and 6 young myopes for up to 8 D accommodation stimulus with a psychophysical technique and its variants. An objective technique using the multifocal electroretinogram was developed and evaluated with 5 emmetropes. Results: Using the psychophysical technique, the SCE directionality increased by similar amounts in both emmetropes and myopes as accommodation increased, with an increase of 15-20% with 6 D of accommodation. However, there were no significant orientation changes. Additional measurements showed that most of the change in the directionality was probably an artefact of optical factors such as higher-order aberrations and accommodative lag rather a true effect of accommodation. The multifocal technique demonstrated the presence of the SCE, but results were noisy and too variable to detect any changes in SCE directionality or orientation with accommodation. Conclusion: There is little true change in the SCE with accommodation responses up to 6 D in either emmetropes or myopes, although it is possible that substantial changes might occur at very high accommodation levels. The objective technique using the multifocal electroretinogram was quicker and less demanding for the subjects than the psychophysical technique, but as implemented in this thesis, it is not a reliable method of measuring the SCE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We determined the foveal Stiles-Crawford effect (SCE) as a function of up to 8D accommodation stimulus in six young emmetropes and six young myopes using a psychophysical two-channel Maxwellian system in which the threshold luminance increment of a 1 mm spot entering through variable positions in the pupil was determined against a background formed by a 4 mm spot entering the pupil centrally. The SCE became steeper in both groups with increasing accommodation stimulus, but with no systematic shift of the peak. Combining the data of both groups gave significant increases in directionality of 15-20% in horizontal and vertical pupil meridians with 6D of accommodation. However, additional experiments indicated that much of this was an artefact of higher order aberrations and accommodative lag. Thus, there appears to be little changes in orientation or directionality in the SCE with accommodation stimulus levels up to 6 D, but it is possible that changes may occur at very high accommodation levels

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate the contribution of matrix degradation in the two-layer avian sclera to the development of myopia. Tissue inhibitor of metalloproteinase-2 (TIMP-2) was used to inhibit chick scleral collagen degradation with (3)H-proline, a marker for this effect. Ex vivo scleral culture experiments confirmed TIMP-2 doses for in vivo experimentation. Ocular growth and refractive response to exogenous TIMP-2 (11.25, 2.25, and 0.45 picomoles, plus vehicle only) were monitored in 7-day-old chicks during the induction of myopia over 4 days with a translucent occluder. Collagen degradation was assessed, in whole sclera and in separated scleral layers by using the same paradigm (11.25 picomoles TIMP-2; vehicle only).Approximately 60% of collagen degradation was inhibited with low (2 nM) doses of TIMP-2 in the ex vivo sclera. Degradative activity in the in vivo chick sclera increased significantly (46%) during myopia development, with all the altered activity confined to the fibrous layer. Addition of TIMP-2 significantly reduced (by 46%) this accelerated scleral collagen degradation, also by acting in the fibrous layer. TIMP-2 had no significant effect on (3)H-proline incorporated in the cartilaginous scleral layer and cornea. Despite inhibiting collagen degradation TIMP-2 had no significant effect on myopia development. Increased collagen degradation is a feature of scleral remodeling in chick myopia development, but is confined to the fibrous scleral layer. Significant inhibition of this collagenolytic activity with TIMP-2 has little effect on refractive error development, suggesting that collagen degradation in the sclera contributes little to the development of myopia in the chick.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare tear film osmolarity measurements between in situ and vapor pressure osmometers. Repeatability of in situ measurements and the effect of sample collection techniques on tear film osmolarity were also evaluated.

Methods: Osmolarity was measured in one randomly determined eye of 52 healthy participants using the in situ (TearLab Corporation, San Diego, CA) and the vapor pressure (Vapro 5520; Wescor, Inc., Logan, UT) osmometers. In a subset of 20 participants, tear osmolarity was measured twice on-eye with the in situ osmometer and was additionally determined on a sample of nonstimulated collected tears (3 µL) with both instruments.

Results: Mean (SD) tear film osmolarity with the in situ osmometer was 299.2 (10.3) mOsmol/L compared with 298.4 (10) mmol/kg with the vapor pressure osmometer, which correlated moderately (r = 0.5, P < 0.05). Limits of agreement between the two instruments were -19.7 to +20.5 mOsmol/L. Using collected tears, measurements with the vapor pressure osmometer were marginally higher (mean [SD], 303.0 [11.0] vs 299.3 [8.0] mOsmol/L; P > 0.05) but correlated well with those using the in situ osmometer (r = 0.9, P < 0.05). The mean (SD) osmolarity of on-eye tears was 5.0 (6.6) mOsmol/L higher than that of collected tears, when both measurements were conducted with the in situ osmometer. This was a consistent effect because the measurements correlated well (r = 0.65, P < 0.05).The in situ osmometer showed good repeatability with a coefficient of repeatability of 9.4 mOsmol/L (r = 0.8, P < 0.05).

Conclusions: Correlation between the two instruments was better when compared on collected tear samples. Tear film osmolarity measurement is influenced by the sample collection technique with the osmolarity of on-eye tears being higher than that of collected tears. This highlights the importance of measuring tear film osmolarity directly on-eye. The in situ osmometer has good repeatability for conducting this measurement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enamel white spot subsurface lesions compromise esthetics and precede cavitation; therefore, they must be halted. The aim of this study was to evaluate the effect of a caries infiltration technique and fluoride therapy on the microhardness of enamel carious lesions. Subsurface carious lesions were produced in 60 bovine specimens with polished enamel surfaces. The specimens were divided into four groups (n=15), according to the treatment used: CON, control immersion in artificial saliva; DF, daily 0.05% fluoride solution; WF, weekly 2% fluoride gel; and IC, resin infiltration (Icon). The specimens were kept in artificial saliva and evaluated for microhardness at five points: baseline, after caries production, after four and eight weeks of treatment, and a final evaluation after being submitted to a new acid challenge. The repeated-measures analysis of variance showed significant differences according to the type of treatment (TREAT; p=0.001) and time of evaluation (EV; p=0.001). The results of the Tukey test were TREAT: CON = 45.18 (+/- 29.17)a, DF = 107.75 (+/- 67.38)b, WF = 83.25 (+/- 51.17)c, and IC = 160.83 (+/- 91.11)d. Analysis of correlation between the TREAT and EV factors showed no significant differences for DF (138.63 +/- 38.94) and IC (160.99 +/- 46.13) after the new acid challenge. The microhardness results in decreasing order after eight weeks were IC > DF > WF > CON. It was concluded that the microhardness of carious lesions increased with the infiltration of resin, while the final microhardness after a new acid challenge was similar for DF and IC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Various mesoporous catalysts with vanadium loadings between 0.5 and 6 V wt.% and surface areas around 1300 m(2)/g were synthesized using the isomorphous substitution (IS) and molecular designed dispersion (MDD) techniques. Their catalytic properties were tested using toluene as a model VOC in a fixed bed reactor at temperatures between 300 and 550 degrees C. It was found that during the oxidation of toluene, over V-HMS synthesized via IS, conversion of toluene mainly results in carbon oxides, benzene, benzaldehyde and water. Total conversion is greatly improved when the vanadium content is increased from around 1.5 to 3.0 wt.%, but an increase in the textural porosity (V-TEX/V-MESO) from 0.3 to 0.6 had no discernable effect on the conversion. This can be explained by the fact that a V-TEX/V-MESO as low as 0.3 is sufficient to facilitate the access of toluene into the framework confined mesopores without any molecular transport limitations. However, when using V-HMS synthesized by MDD, conversion of toluene is greatly improved when the V-TEX/ V-MESO ratio is increased from 0.1 to 0.6. This is because the diffusion limitations are minimized by this increase. V-HMS synthesized via MDD does not exhibit selectivity to benzaldehyde, favoring total oxidation to CO and CO2. This different oxidation mechanism can be explained in terms of location, accessibility and number of active species on the surface of the HMS support. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Previous studies have demonstrated an increase in macular pigment optical density (MPOD) with lutein (L)-based supplementation in healthy eyes. However, not all studies have assessed whether this increase in MPOD is associated with changes to other measures of retinal function such as the multifocal ERG (mfERG). Some studies also fail to report dietary levels of L and zeaxanthin (Z). Because of the associations between increased levels of L and Z, and reduced risk of AMD, this study was designed to assess the effects of L-based supplementation on mfERG amplitudes and latencies in healthy eyes. METHODS: Multifocal ERG amplitudes, visual acuity, contrast sensitivity, MPOD and dietary levels of L and Z were assessed in this longitudinal, randomized clinical trial. Fifty-two healthy eyes from 52 participants were randomly allocated to receive a L-based supplement (treated group), or no supplement (non-treated group). RESULTS: There were 25 subjects aged 18-77 (mean age ± SD; 48 ± 17) in the treated group and 27 subjects aged 21-69 (mean age ± SD; 43 ± 16) in the non-treated group. All participants attended for three visits: visit one at baseline, visit two at 20 weeks and visit three at 40 weeks. A statistically significant increase in MPOD (F = 17.0, p ≤ 0.001) and shortening of mfERG ring 2 P1 latency (F = 3.69, p = 0.04) was seen in the treated group. CONCLUSIONS: Although the results were not clinically significant, the reported trend for improvement in MPOD and mfERG outcomes warrants further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis will show how to equalise the effect of quantal noise across spatial frequencies by keeping the retinal flux (If-2) constant. In addition, quantal noise is used to study the effect of grating area and spatial frequency on contrast sensitivity resulting in the extension of the new contrast detection model describing the human contrast detection system as a simple image processor. According to the model the human contrast detection system comprises low-pass filtering due to ocular optics, addition of light dependent noise at the event of quantal absorption, high-pass filtering due to the neural visual pathways, addition of internal neural noise, after which detection takes place by a local matched filter, whose sampling efficiency decreases as grating area is increased. Furthermore, this work will demonstrate how to extract both the optical and neural modulation transfer functions of the human eye. The neural transfer function is found to be proportional to spatial frequency up to the local cut-off frequency at eccentricities of 0 - 37 deg across the visual field. The optical transfer function of the human eye is proposed to be more affected by the Stiles-Crawford -effect than generally assumed in the literature. Similarly, this work questions the prevailing ideas about the factors limiting peripheral vision by showing that peripheral optical acts as a low-pass filter in normal viewing conditions, and therefore the effect of peripheral optics is worse than generally assumed.